The data behind an NGERs report — diesel, oils, SF6 and more.

Every figure in the report starts as a document at a site: a fuel invoice, a tank dip, a switchgear register. What to collect for each source, what counts as evidence, and where the gaps usually are.

By Assay Group, NGERs practitioner. A 16-minute read, last reviewed , with the factors that apply to 2025–26 reports.

The Measurement Determination is precise about how to turn a kilolitre of diesel or a kilogram of SF6 into tonnes of CO₂-e. It says much less about where the kilolitres went, who holds the invoice, or why the switchgear register is two years out of date — and that is where most of the work in an NGERs report sits. This guide goes source by source through the data a multi-site business typically needs, the evidence behind it, and the details that catch people out.

It is the companion to How NGERs reporting works, which covers who reports, the key dates and the process end to end.

From a receipt to a reported figure

Almost every number in an NGERs report is built the same way: a quantity, multiplied by an energy content factor to give gigajoules, multiplied by an emission factor to give tonnes of CO₂-e. The quantity is yours — kilolitres, cubic metres, kilowatt-hours, kilograms. The factors are set in Schedule 1 of the National Greenhouse and Energy Reporting (Measurement) Determination 2008. The Determination is amended most years, and the electricity factors change every year, so use the compilation that applies to the year being reported rather than the factors in last year's workbook. The National Greenhouse Accounts Factors published by DCCEEW repeat most of the same numbers, but DCCEEW itself says they should not be used for NGERs reporting; the Determination is the source.

Worked example: diesel in on-site generators, Method 1
Diesel delivered and burned100 kL
× energy content38.6 GJ/kL
= energy consumed3,860 GJ
× emission factor (CO₂ + CH₄ + N₂O)70.2 kg CO₂-e/GJ
= scope 1 emissions271 t CO₂-e

That is about 2.7 tonnes of CO₂-e for every kilolitre of diesel — a useful sense check against any site's figure. The gigajoules in the middle are reported too, as energy consumed, and they count towards the energy thresholds whatever the emissions come to. Three things follow from the arithmetic:

  • Fuels have to be kept apart. Diesel, petrol, LPG, lubricating oil and grease each carry their own factors, and the same fuel can carry different factors depending on what it was burned for. A total fuel spend is not an input.
  • Units have to be right. Liquid fuels are reported in kilolitres, while dockets and fuel cards count litres — the Regulator's own reporting tips remind reporters to convert. Every conversion between a docket and the report is a chance for a slip of a factor of a thousand.
  • The quantity is what gets examined. The factors are published. The litres are what a reviewer traces back to a document.

Diesel and other liquid fuels

For most businesses outside electricity generation, diesel is the largest scope 1 source and the most scattered one. It arrives by tanker into site tanks, through fuel cards at service stations, and inside contractors' invoices. Two decisions shape how it is reported: how the quantity is measured, and what the fuel was used for.

How the quantity is measured

The Determination sets out the ways a quantity of liquid fuel may be established as lettered criteria (sections 2.49 to 2.53):

  • Criterion A — the quantity delivered to the facility during the year, as shown on the vendor's invoices. Delivery records count as invoices. There is no adjustment for fuel still in the tank.
  • Criterion AA — invoiced deliveries, adjusted for the estimated change in the stock held on site across the year.
  • Criterion AAA — direct measurement of the fuel, with equipment calibrated to a recognised measurement standard.
  • Criterion BBB — an estimate, using accepted industry measuring devices or industry practice.

Where the fuel was bought, only A, AA or AAA are available — and that includes fuel a contractor buys for work on your facility, so an estimate is rarely an option for diesel. The choice also sticks: once a facility reports on AA, or on AAA measured at the point of use, it has to keep using that criterion in later years. The Regulator's guidance treats a site fuel management system as a way to split an invoiced total between uses, not as direct measurement at the point of combustion. Pick the criterion that matches the records the site actually keeps, and write down why.

Stationary or transport

Diesel is also split by purpose, because the stationary and transport factors differ. The Determination defines transport energy purposes as including transport by vehicles registered for road use, rail, waterborne and air transport; everything else is stationary, and the Regulator's guidance says in terms that vehicles which are not road-registered are stationary. So the diesel in haul trucks, loaders, excavators and a site's generators is stationary energy, however far the machines drive — and the diesel in a road-registered ute is transport, even if it never leaves the site.

Within transport, the factors vary by vehicle. Method 1 uses one set of general transport factors; Method 2 separates post-2004 vehicles and heavy vehicles by the emission standard they were built to, and from 2026–27 the Determination adds Euro V and Euro VI truck categories. A fleet register that records each vehicle's registration, type, year and emission standard is what makes the split defensible.

Biodiesel, renewable diesel and ethanol carry a zero CO₂ factor — only their methane and nitrous oxide count — but blends are reported by component: E10 is reported as petrol and ethanol, not as one fuel. Where renewable diesel arrives through shared supply infrastructure, the renewable share can be claimed only with the invoices, delivery evidence and biomass certificate the Determination asks for; without them, all of it is reported as its fossil equivalent.

Collect
  • Supplier invoices and delivery dockets for every bulk delivery, in litres
  • Fuel card statements, by vehicle
  • Tank dips or gauge readings at 1 July and 30 June, if you report on criterion AA
  • Fuel bought or dispensed by contractors working on your sites
Keep as evidence
  • Deliveries that reconcile to accounts payable
  • Stock readings that are signed and dated
  • A fleet and plant register showing which equipment is road-registered
Watch for
  • Fuel cards held by contractors or staff who are not on the register
  • Diesel buried in a maintenance or hire contract as a lump sum
  • Litres entered as kilolitres

Two cross-checks are worth running every year. The Regulator's guidance suggests comparing the dollar value of fuel purchases in the ledger with the kilolitres reported: the implied price per litre should look like a diesel price. And the litres in the business's fuel tax credit claims are an independent count of much the same fuel. Neither will match exactly, but a gap nobody can explain is a question a reviewer will ask.

Lubricating oils and greases

Oils and greases are the source most often left out, because nobody thinks of them as fuel. NGERs does. Petroleum-based oils (other than oil used as fuel) and petroleum-based greases each have their own line in Schedule 1 of the Regulations, and the definitions reach synthetic equivalents and recycled oils as well. That takes in engine, gear and hydraulic oils, and the gearbox oil and grease in every wind turbine.

Both have an energy content of 38.8 GJ per kilolitre, close to diesel's, but far lower CO₂ factors: 13.9 kg CO₂-e/GJ for oils and 3.5 for greases, against 69.9 for diesel. The difference is oxidation. Method 1 assumes that about 20% of the oil and 5% of the grease is burned off in use; the rest is drained, recovered or disposed of.

Two consequences follow. First, energy consumed is reported on the whole volume: the Regulator treats oil as consumed as soon as it leaves its container, so 10 kilolitres of oil is 388 GJ of energy consumed, even though its emissions come to about 5.4 t CO₂-e. Second, the default can be improved on. The Determination lets a facility replace the assumed oxidation with its own figure, calculated from the oil transferred off site — which is where waste-oil collection records earn their keep.

Collect the volumes for every source, however small: the Determination carries small-quantity provisions for oils and greases, and whether one reaches a particular source is a question to settle against the current instrument rather than to assume. Oil burned as a fuel is a different fuel type altogether, and belongs with the fuels rather than the lubricants.

Collect
  • Purchases of oils and greases by product, with volumes
  • Oils and greases used on your equipment by maintenance contractors, including turbine service providers
  • Waste oil collected for recycling or disposal, if you calculate your own oxidation factor
Keep as evidence
  • Supplier invoices or contractor service reports that state litres
  • Product data sheets giving density, where grease is bought by the kilogram
  • Waste-oil collection dockets
Watch for
  • Lubricants bought by the service contractor and buried in a service invoice
  • Grease recorded in kilograms with no conversion to kilolitres
  • Waste-oil dockets mistaken for consumption

SF6 in switchgear

Sulphur hexafluoride is the insulating gas in most high-voltage switchgear and circuit breakers: the substation at a solar or wind farm, the gas-insulated switchgear at a large industrial site, and often the medium-voltage switchgear inside each wind turbine. It is the most potent greenhouse gas the scheme covers, with a global warming potential of 23,500. One kilogram leaked is 23.5 tonnes of CO₂-e — as much as burning about 8.7 kilolitres of diesel.

SF6 is not scoped the way refrigerants are: Part 4.5 of the Determination deals with emissions from gas-insulated switchgear and circuit breakers, and the stock of gas held in the equipment is part of what is reported. Treat every piece of switchgear as in scope until it is shown otherwise. There are three methods:

  • Method 1 applies a default annual leakage rate of 0.89% to the stock of SF6 held — based on the equipment's nameplate capacity, or on opening stock adjusted for gas added and removed. It needs a good equipment register and little else.
  • Method 2 is a mass balance: gas in storage at the start of the year, less storage at the end, plus gas acquired (including the charge inside new equipment), less gas sold, returned or destroyed, less the net increase in nameplate capacity.
  • Method 3 adds up losses event by event: top-ups of leaking equipment, failures, filling and handling losses, and gas lost at decommissioning.
Worked example: switchgear holding 300 kg of SF6, Method 1
SF6 held in equipment300 kg
× global warming potential23,500
= stock7,050 t CO₂-e
× default leakage rate0.89%
= scope 1 emissions63 t CO₂-e

Method 1 gives that figure whether or not any gas actually leaked: it is a default rate applied to what the equipment holds, not a measurement, and it comes to about the same as 23 kL of diesel every year. Methods 2 and 3 reflect what actually happened, which can come out lower or higher, but they depend on records a contractor may not keep unless asked. If a measured method comes out at zero, the activity is still reported, as zero.

Ownership needs a decision too. Switchgear in a connection substation is often owned and maintained by the network service provider, and the switchgear in a turbine may sit under the manufacturer's service agreement. Whether each item is inside your facility is an operational control question: decide it once, and write the reason down.

Collect
  • A register of every item of equipment containing SF6, with its nameplate charge in kilograms
  • Equipment commissioned or retired during the year
  • Gas bought, topped up, recovered, returned or destroyed
Keep as evidence
  • Nameplates or manufacturer data sheets
  • Service and top-up records from the high-voltage contractor
  • Cylinder purchase and return records
Watch for
  • Turbine switchgear missing from the register because it arrived inside the turbine
  • Top-ups during maintenance that never reach the register
  • A register that has not been touched since commissioning

Refrigerants

Refrigerants are the source where scope is most often argued, in both directions. Whether a given unit counts turns on three facts about it, so those are the three to have on hand before the question is put to the Determination:

  • what the equipment is and how much refrigerant it holds: commercial air conditioning, commercial refrigeration and industrial refrigeration are treated as their own categories, and the charge per unit matters;
  • which gas is in it, and that gas's global warming potential: R-22 is an HCFC rather than an HFC, R-32's GWP is under 1,000, and a blend such as R-410A contains R-125, so a blend has to be read by its components; and
  • the facility's principal activity, which the scope rules turn on as well.

Commercial property is where this bites hardest: a building owner's principal activity, a large chiller holding well over 100 kg, and a blend nobody has looked up. Build the equipment register first — unit, location, gas, charge — and take the scope question from there. It is a question worth getting a second opinion on, in either direction.

Where the rule applies, Method 1 is again a default annual leakage rate applied to the gas held in the equipment: 9% for commercial air conditioning, 23% for commercial refrigeration and 16% for industrial refrigeration.

Collect
  • An equipment register: each unit's type, refrigerant and charge in kilograms
  • Refrigerant added, recovered and disposed of during the year
Keep as evidence
  • Nameplates, and service records from the refrigeration contractor
Watch for
  • Units logged without their gas or charge, so the scope question cannot be answered
  • Units just over 100 kg left off the register
  • A blend reported as if it were a single gas

Electricity, bought and generated

Purchased electricity is scope 2: the kilowatt-hours consumed, multiplied by the factor for the grid the facility is connected to. That location-based figure is mandatory. A market-based figure, which recognises renewable certificates surrendered, can be reported alongside it but never instead of it, and from 2025–26 a group that uses the market-based method for one facility has to use it for all of them. Collect the kilowatt-hours for every connection, including the small ones: a site that looks too small to matter still has to be counted before anyone can say what it does to the numbers.

Location-based scope 2 factors, kg CO₂-e per kWh
Grid2025–262026–27
NSW and ACT0.640.60
Victoria0.780.74
Queensland0.670.65
South Australia0.220.21
WA (SWIS)0.500.45
Tasmania0.200.21
NT (DKIS)0.560.55

The factors move every year, and in most grids they fall as the grid adds renewable generation — so the same consumption usually produces a smaller number the following year. That is worth saying out loud before someone reads a falling scope 2 figure as an efficiency gain.

For evidence of consumption, the Determination accepts invoices, contractual arrangements or industry metering records, and the Regulator's guidance prefers the most accurate meter available, such as the revenue meter at the network connection point. In practice that usually makes the interval data behind each NMI a better source than the bill: invoices can carry estimated reads, and their billing periods rarely line up with 30 June. A bill that straddles the year end can be split by days or another reasonable method, as long as the method is documented and applied consistently. Leave out any unaccounted-for energy line on the invoice.

Generators report energy produced as well. Electricity exported is measured at the connection point, under the market's metering rules; electricity used on site is the terminal output less what was exported or supplied elsewhere. The part that trips up solar and wind farms is the other direction: electricity a generating site imports — overnight, during outages, for auxiliary load — is purchased electricity like any other, with scope 2 emissions. And the Regulator's reporting tips say it plainly: batteries are not reported as producing electricity.

Collect
  • A list of every NMI at every facility, checked against the site list
  • Interval data or invoices for each NMI, covering 1 July to 30 June
  • For generating sites, export and import data from the connection-point meter
  • For market-based reporting, the certificate surrender records
Keep as evidence
  • Metering data provider files or retailer invoices
  • Settlement or metering statements for exports
  • LGC serial numbers, GreenPower statements or REGO identifiers
Watch for
  • Meters added mid-year, or supply billed by a landlord through an embedded network
  • Estimated reads carried into the annual total
  • A generating site's imports left out because everyone thinks of it as an exporter

Natural gas and LPG

Natural gas is usually the simplest source to evidence, because the retailer's invoice normally states the energy in gigajoules. Where it does, the energy content factor is simply 1; where the quantity is in cubic metres, the Determination's default for pipeline gas is 39.3 MJ per cubic metre, on a gross calorific value basis. Pipeline gas carries a combined emission factor of 51.53 kg CO₂-e/GJ. The usual gaps are sites that share a meter, and bills that straddle 30 June.

LPG arrives by delivery, and needs the same treatment as diesel: quantities from invoices, stock adjustments if you use them, and a decision about purpose. LPG in forklifts that are not road-registered is stationary energy, on the same rule as off-road diesel. Stationary and transport LPG even have different energy contents — 25.7 and 26.2 GJ per kilolitre — so the split changes the energy figure, not just the emissions. Cylinder LPG is usually sold by the kilogram and has to be converted to kilolitres.

Collect
  • Gas invoices for each meter, in gigajoules or cubic metres
  • LPG delivery dockets and cylinder exchange records
Keep as evidence
  • Retailer invoices, with actual meter reads where the invoices were estimated
  • Delivery records that state volume or mass
Watch for
  • Cylinder LPG bought by the kilogram with no conversion to kilolitres
  • Forklift LPG reported as transport
  • Estimated gas reads never trued up

What the evidence file should hold

The legal standard is short: records have to be enough to show the report is accurate, they have to be easy and quick to inspect, and they have to be kept for five years from the end of the reporting year (section 22 of the National Greenhouse and Energy Reporting Act 2007). What the Regulator recommends keeping is more specific, and it is also what an assurance reviewer will ask for. For each facility and each year:

  • A list of the facility's reportable activities and emission sources.
  • The activity data, and the source documents behind it: invoices, dockets, meter data, equipment registers.
  • The method and measurement criterion used for each source, and why it was chosen.
  • How the data was collected and calculated, including the factors used and where they came from.
  • Every estimate: what was estimated, why, and how.
  • The decisions about the controlling corporation, the group and each facility's boundary.

The Regulator also encourages a basis of preparation — a short document describing the facility, its data sources, its methods and its key assumptions — submitted with the report. Writing one is the quickest way to find out which of the above is missing.

A few rules govern what happens when data is missing. A failed meter can be covered by an estimate for up to six weeks in a year; beyond that, the Regulator has to be told in writing (section 1.19 of the Determination). A method, once chosen, generally has to stay in use for four years unless you move to a higher one (section 1.18). And genuinely small sources, within the limits for incidental emissions and energy in regulation 4.27, may be estimated by a simpler method, provided the report identifies them as such. Each of these is a decision to record, not a place to stop looking.

A data request that works

Most of this already exists somewhere in the business — in accounts payable, with the maintenance contractor, on a site's shared drive. The work is getting it back complete, in a form that holds up. A data request that works:

  1. Goes to each site and each contractor separately, naming the sources that apply to them.
  2. Asks for documents, not totals: the invoices and the meter data, not a number typed into an email.
  3. States the units wanted (litres, kilograms, kilowatt-hours, gigajoules) and the period, 1 July to 30 June.
  4. Asks for stock readings at both ends of the year wherever fuel is stored on site.
  5. Asks for the SF6 and refrigerant registers, updated for equipment added or removed.
  6. Asks contractors for the fuel, oils and greases they used on your equipment.
  7. Goes out on a calendar, quarterly rather than once in September, and records who sent what, and when.

The first year of collecting data this way is the hard one, because it is the year the gaps come to light. After that, the same request goes out on the same dates and most of it comes back on its own.

Sources

General information only, current at the time of writing. It is not legal or professional advice. Factors and rules are those in the Measurement Determination for 2025–26 reports, with 2026–27 changes noted where they differ. Verify against the current legislative instruments before relying on them.

A free 30-minute process audit.

Walk through how your NGERs reporting runs today and leave with the two or three things worth fixing first, whether or not you go any further.

  • Which sites you report and where each boundary sits
  • Where the data lives — meters, invoices, contractors — and how it gets back to you
  • How the figures are calculated and reviewed before lodgement
  • Whether the evidence would hold up in an assurance review